As part of the building approval process, a Section J report is generally required to demonstrate how a proposed building meets the energy efficiency requirements of the National Construction Code (NCC).

SALT prepares Section J reports for developers, builders, architects and other project stakeholders Australia-wide, using either the Deemed to Satisfy (DTS) method or the JV3 verification method to suit project requirements.

Get in touch with our team to discuss your project and how we can support your Section J compliance requirements.

What a Section J Report Covers

Section J of the National Construction Code (NCC) sets out the energy efficiency requirements for Class 2-9 buildings. A Section J report considers how a proposed building addresses the relevant requirements based on its building classification and climate zone.

The key areas covered under Section J include:

  • Part J1, Building Fabric
  • Part J2, Glazing
  • Part J3, Building Sealing
  • Part J5, Air Conditioning and Ventilation Systems
  • Part J6, Artificial Lighting and Power
  • Part J7, Hot Water Supply, Swimming Pool and Spa Pool Plant
  • Part J8, Maintenance and Monitoring Facilities

SALT prepares Section J reports using two assessment methods:

  • Deemed to Satisfy (DTS): Assesses the proposed design against the NCC’s prescriptive requirements to demonstrate compliance.
  • JV3 Assessment: Compares the proposed building’s energy performance against a reference building to demonstrate compliance, allowing greater flexibility in design.

Our team can help determine the appropriate assessment method for your project and prepare the documentation needed to demonstrate Section J compliance.

Projects and Developments That Need a Section J Report

Section J reporting is typically undertaken during the design and approval stages to demonstrate that a proposed building meets the NCC’s energy efficiency requirements.

Projects that may require a Section J report include:

  • Residential developments (communal areas and shared facilities)
  • Accommodation
  • Commercial developments
  • Industrial developments
  • Public buildings
  • Mixed-use developments

What to Have Ready for Your Section J Assessment

To get started, project teams should have the following information available:

  • Project details including the site address, building classification, proposed use, and current approval stage.
  • Architectural drawings showing floor plans, elevations, sections, roof plans, and building orientation.
  • Building fabric specifications detailing wall, roof and floor construction, insulation types, and material specifications.
  • Glazing specifications covering window and glazed door dimensions, frame types, glass specifications, and external shading.
  • Mechanical services information outlining air-conditioning and ventilation system types.
  • Lighting details including lighting layouts, fixture types, wattages, quantities, and control systems.
  • Hot water system details and, where applicable, swimming pool specifications.
  • Supporting documentation such as consultant reports and project specifications.

JV3 assessments may require additional design details to complete the energy modelling and performance comparison.

Why Choose SALT for Your Project

Here’s why clients choose SALT for their Section J reporting requirements:

  • 30+ years of combined industry experience delivering sustainable design advice across a range of building and development projects.
  • Accredited sustainability professionals with the expertise to prepare Section J reports using both DTS and JV3 assessment methods.
  • Our Integrated Management System holds certifications for ISO 9001, ISO 45001 and ISO 14001, covering quality, occupational health and safety, and environmental management.
  • Consulting services are delivered Australia-wide, across metropolitan, regional and rural areas.
  • Responsive and timely delivery of Section J reports to help keep projects moving through the approval process.

Meet the team behind SALT’s work on our team page.

Planning a Project? Contact SALT Today

SALT prepares Section J reports for building projects of varying sizes and complexity. Contact SALT today to discuss your Section J reporting requirements.

FAQs

How much does a Section J report cost?

The cost of a Section J report depends on several factors, including the size of the building, project complexity, the scope of the assessment, and the compliance method selected. A straightforward development assessed using the Deemed to Satisfy (DTS) method may require less analysis, while larger or more complex projects may require additional analysis, and a JV3 assessment may be used where the design does not meet the DTS requirements. Contact our team for a project-specific quote.

What is the difference between Section J and JV3 compliance?

Section J outlines the NCC’s energy efficiency requirements for applicable buildings. JV3 is one method of demonstrating compliance, using energy modelling to compare the proposed building with a reference building. Unlike DTS, which follows set requirements, JV3 allows more flexibility in the building design.

Can a Section J report be updated if the building design changes?

Yes. If the building design changes after a Section J report has been prepared, the assessment may need to be reviewed and updated to reflect the revised plans and specifications. Our team can review the updated documentation and advise whether revisions to the report are required.